Shower toilet: which connections do I need?

In short: The Soho 4.0 with Taharet function works purely mechanically and needs no electricity: the cold water version only needs a cold water connection at the toilet, the thermostat version also needs a hot water connection. Only the AquaComfort electronic seat needs a socket.

The details

  • Soho 4.0 cold water: operated with the rotary control on the side, spray intensity continuously adjustable; the flexible hose for the water connection is included.
  • Soho 4.0 with thermostat: mixes hot and cold water mechanically, with temperature and spray intensity set on the control knob at the side. Towards minus the water gets cooler than 38 °C, towards plus warmer; the nozzle can be aligned by hand.
  • The connection is made behind the toilet: the hoses supplied run from the control knob through the ceramic to the back and on to the water connections in the wall (cold water, plus hot water for the thermostat version). Have your installer provide a shut-off valve for this in an accessible place.
  • AquaComfort seat: cold water connection G 1/2 inch, power 220 V, heating output up to 1400 W, protection class IPX4; with warm water, seat heating, night light and self-cleaning nozzle. Water pressure 0.75 to 8 bar; connection hose and filter are included; it is connected to cold water only (4 to 35 °C).
  • The Soho 4.0 toilets are available in gloss white, matt black and as a compact model; all are rimless with vortex flush. Replacement nozzles and replacement valves for the Taharet function are available on request.
  • Our installation frame with shower toilet connection already has the water routing prepared for this.

What to do

  1. Before installation, clarify which connections are possible behind the toilet: cold water only, cold and hot water, or electricity as well.
  2. Choose the matching model and have the installer set the water connection.
  3. After installation, check the connection for leaks before the wall is closed or the toilet is finally bolted on.

Good to know

The water connection must be in place before the toilet is installed, because it will later be behind the ceramic. The socket for the AquaComfort must be earthed, splash-proof and protected by an RCD; the manual recommends a height of around 50 cm above the floor and an easily accessible shut-off valve in the same room.